Simulate your DCFC site for free

Increase charging power utilization and site uptime with evPower Edge Box

The Edge Box adds measurement and control at the point of supply - feeding AI-DLM with real-time data, and opening the site to behind-the-meter (BTM) assets and grid services.
DC fast-charging sites are frequently limited in power and struggle to optimize uptime, both magnified by AC/DC conversion and dynamics of high-power equipment.

Challenges

Site power is under-used

Chargers are set in kW, the grid connection is rated in kVA. To stay safe, the site is capped at the lower of the two to avoid circuit-breaker tripping.

Higher peak power. More energy sold.

Real-time current and voltage measurement tunes the load management.

Conversion loss costs margin

Charger's power modules draw more on the AC side than they deliver on the DC side, and the gap widens as they continuously degrade.

Tighter load management. Alerts when performance degrades.

The conversion coefficient is measured per charger, continuously.

Power quality costs uptime

Grid instability and unmanaged load negatively impact the dynamics of high-power charging.

Faster recovery, failure root-cause analysis, real-time alerts.

Continuous power quality monitoring, correlated with charging activity.

Unmanaged load limits charging

Stores, car wash and other variable loads draw from the same grid input as the chargers.

More power for charging. Higher energy sales.

Adaptive load balancing (ALB) equalizes the resource continuously to safely maximize peak power.

How it connects

GRID MV / LV 3× CT AC BUSBAR DC FAST CHARGERS any brand · any CPMS SITE LOAD stores · carwash · other BTM ASSETS BESS · PV · genset metering OCPP · MODBUS ALB metering MODBUS · CAN · SNMP evPower EDGE BOX DIN rail · 24 V DC · fanless LTE / LAN evPower CLOUD AI-DLM · dashboards · NOC Power Measurement & control Network GRID MV / LV 3× CT AC BUSBAR DC FAST CHARGERS any brand · any CPMS OCPP · MODBUS SITE LOAD stores · carwash · other ALB metering BTM ASSETS BESS · PV · genset MODBUS · CAN · SNMP metering evPower EDGE BOX DIN rail · 24 V DC · fanless LTE / LAN evPower CLOUD AI-DLM · dashboards · NOC Power Measurement & control Network

Asset connections

Read

Power meters · Inverters · PV charge controllers · environmental, parking and LPR sensors. 1 Hz acquisition, 1 ms log replay, 7-day edge buffering with backfill.

Control

Controlled by evPower's techno-economic model, tailored for each asset specification.

  • BESS
  • GenSet
  • EV chargers
  • H2FC

Observability

Live and historical view across sites and chargers. Alerts with configurable thresholds. Any charging session reconstructable to the millisecond.

Security

Traffic off site rides a VPN, on a private APN. Encrypted transport, role-based access control, and an audit trail on every change.

Fail-safe operation

Safely maintain power limits
  • Sequential validation before every setpoint is issued
  • Continuous peak control, sustained whether or not a session is running
Surviving faults
  • Safe operation through communication loss (one charger or the whole site), power loss, and charger bugs or misconfiguration
  • Dual Ethernet, dual power input, master-master high-availability controllers
One hardware · Multiple software services

Edge Box software packages

Software licences activated on the installed evPower Edge Box.

BASICSite power analysis and control + ALBAdaptive balancing with non-controllable load + BTMOrchestration of BESS, PV and genset
1 Hz metering at the point of connection●●●
AI-DLM charger orchestration, kVA-aware●●●
Per-charger dynamic conversion coefficient●●●
Live power health, anomaly alerts, 1 ms log replay●●●
Local technician interface●●●
Balance power usage with unmanaged co-located loads○●●
Higher charger oversubscription using a shared grid input○●●
BESS · PV · Genset orchestration○○●
Techno-economic asset model○○●
Peak shaving and time-of-use arbitrage○○●
Local (network-free) power managementOPTIONALOPTIONALOPTIONAL